Royce Da 5 9 Pharrell, Why The Fuss Everquest Guild, Best Nycha Developments In Brooklyn 2019, Sox Controls Examples, Diy Tennis Ball Launcher, Raeven Khan Age, Hp Pavilion Laptop Hard Drive Replacement, Animal Crossing: New Horizons Pattern Maker, " />

lebanese mexican food

Written by on Luty 22, 2021 in Bez kategorii

These cells allow to reach 4500 cycles at 80% DoD. I have a 100 watt panel on the roof and another 200 watts in a portable suitcase in case I need it, and for emergencies, a 2000 watt Yamaha inverter generator. During absorption, the charger applies a constant voltage, called the “absorption voltage.” As the battery’s open-circuit voltage approaches the absorption voltage, the current flow steadily decreases down to zero. 12 V LiFePO4 charger recommended. Lithium batteries I recommend: https://www.mobile-solarpower.com/lithium-batteries.html~~~~~Does off-grid solar confuse you? Thanks for the info. We are so sorry to hear that this is happening to your rig. If I want to charge them now in my home to verify they are ok when I receive them from BB, what is the suggested way to charge them? Our charge efficiency factor is 100%. 110A 12V Battery Lithium Ion Power Cell Technology A Drop In Replacement & Upgrade from AGM, Gel or Lead Acid Batteries.The Smart Battery 12V 110AH Lithium Ion Battery is the Ultimate High Performance solution for virtually any 12v power application. No need to add a battery disconnect for charging. Hi Andy, great question! I read above in response to comments and in the manual that they have the sensor that will shut off the current to the battery when its less than 25 degrees. We did not intend to present misleading data, we believe that the LFP chemistry’s performance speaks for itself as to why it is a viable option over AGM. can I leave my rv plugged into shore power for an extended period of time with out harming the batteries. My concern is that the ARC-50 display almost always shows the status as “Constant Voltage DC 14.3V.” Very rarely do I see the status as “Quiet 13.6V.” It seems I’m holding the batteries at high voltage way too much. I then turned on the PD4575LI converter. The issue with this is that this would drastically limit the AGM battery’s life cycles available to the user. If someone hasn’t spoken the obvious. Does this apply to both discharge and charging currents? We have to replace about 20 of these batteries. I would also like to build a preset for Battleborn based charging settings using the 14.4v bulk/absorbtion charge volts with a float setting of 13.6v. The BMS will allow for a 100 amp continuous discharge, 200 amp discharge for 30 seconds and a higher discharge for a 1/2 second. Sometimes we use campgrounds where we are hooked up to shore power for a number of nights and other times solar is our only source. This 100 Ah LiFePO4 Deep Cycle battery is a 12 V battery in a 6 V form factor that provides you with 3000-5000 life cycles* of power for your outdoor adventures. The chart below compares the amount of power (Watt Hours) per Kilogram these Constant monitoring of each of the four ( Volt) Lithium Cells connected in series . What Is A BMS (Battery Management System). A battery will only sustain damage if the charging voltage applied is significantly higher than the … Typical lead acid chargers can work in some instances but we would have to get the model # for your marine battery charger and check the settings for compatibility. Your email address will not be published. The 50 A circuit breaker did not trip. © Copyright 2021 Battle Born Batteries. I’m trying to ascertain if my (non-Battleborn) battery has a bad cell, or a bad bms. When you charged the AGM in the freezer, did you use temperature compensation? You also can consider getting our newest heated battery as well. Using forward-thinking technology that is powering electric car giants like Tesla, the LiFePO4 can also withstand any damage without exploding, keeping you and your family and friends safe in any event when you're out exploring the world. I thought the answer was a maximum charge rate of C/2. We modeled this test as if we were end users wanting to preserve our life cycle count of our batteries. Thanks for reaching out! What’s best and what do you recommend given you sell both products? Sure, LFP is a superior chemistry in almost every way, but you don’t need to manufacture misleading data and masquerade it as something scientific to poo poo AGM. I’m running with a Progressive Dynamics PD4575LI which always/only outputs a fix 14.6V, and does not apply a proper bulk charging stage. If you have any other questions, feel free to give our sales and tech team a call at 855-292-2831 or send them an email to [email protected]. Please let me know if you have any additional questions. For example, if your charger is 20 amps and you need to charge an empty battery, it will take 5 hours to reach 100%. (LiFePO4) technology this is a battery built to last. This 12Ah battery is LiFePO4 chemistry (Lithium Iron Phosphate). Max Charge Time? Hi Jason, no damage will occur with the Sterling 30 amp charger on a 6 battery bank, but it will take longer to charge. Warning: Risk of fire, explosion, or burn heat above t e 50OC, o s. Do not disassemble, r incinerate. I believe they will be slow and won’t be my first choice. I also have a Tri-metric 2025 -A. I sent in some questions yesterday evening & just after I hit send my computer crashed and so I am not sure if you received my questions. Input Power (W): 600W; 2X) Battery Type & Voltage: CALB CA180FI - Lithium Cell LiFePO4 (3.2V/180Ah); 12 Cells (3 strings of 4); Total 540Ah @ 12.8V … 200 Amp Surge Current (30 Seconds). The initial charge condition was 12.2 V at 58.6 A. We are currently in the process of revamping our FAQ videos so it is certainly something that we will keep in mind throughout. What is the maximum current I might expect your BB10012 to draw with 14.6V applied (likely when it is fully discharged)? This field is for validation purposes and should be left unchanged. Final Charge Stage? system except that it does not have an Alt. And the white paper study itself here: https://battlebornbatteries.com/wp-content/uploads/2020/10/Lead-is-Dead-Cold-Charging-LFP-vs-Lead-Acid.pdf You can find more answers to charging questions at our FAQ page here: https://battlebornbatteries.com/faq/. Battle Born Batteries collects personal information for its internal use. If I am using shore power I expect the battery charge to quickly get to 100% and if I get reasonable solar, the battery should reach 100%. Hi Christine, thanks for reaching out! We know building an electrical system can be overwhelming, so we’re here to help. With our LiFePO4 batteries, we recommend disconnecting all potential power draws from the battery and letting them sit with a full charge, or at least a 50% charge minimum. When I am running the generator or on shore power the batteries will be charged by the Outback FX. The 12V Battle Born Batteries sit comfortably right in the middle of these ranges. If you are storing your rv and wish to have it plugged in, we would recommend a float voltage of 13.6 volts. Please give our sales and tech team a call at 855-292-2831 if you are still having issues with your setup and they can offer resources for the IP65 Victron Smart charger. You can also set the float voltage to the recommended 13.6v after the absorption time is achieved. Hi Bob, thanks for your patience at this time. I currently have 8 ea 6vdc battery hooked in series for 48vdc. This is the first stage of the charging process – typically called the “bulk” charging stage. Features of LiFePO4 Battery Physical Dimension Application 1 LP1 2- 12(1V AH) MH26866 MADEINCHINA LEOCH BATERYCO.,LTD. Hi Corey, thank you for bringing this to our attention. when charging with an IP65 Victron 12v/15A smart charger do I charge each battery individually or do I connect the negative charging alligator clip to one end of the battery bank and the positive alligator clip to the other end of the battery bank? In the case with our lithium batteries its about 20 minutes per battery. I am looking for something in the range of a 50ah, 12V battery. I just received 3 of your 100 ah 12v batteries, do I need to charge them before installing or using them? The charger has a desulfation mode that’s supposed to come on when it thinks the battery needs it and I understand that lithium batteries can be damaged by that. Our batteries don’t necessarily have a reserve capacity that is more of a term used with lead acid batteries, but you are able to use a full 100% of the batteries capacity. Hi Garret, our recommended charge rate is 50 amps per 100 Ah battery in your system. Will a LiFePO4 battery work in this instance as a replacement for the Alphacell 220 GXL lead acid batteries? Sorry I forgot to include my name and email on the first comment I sent. We do not share customer information with any third parties. Please let us know if you have any additional questions. Once the temperature is back up above 25 degrees F, the battery will be able to accept a charge again. The charging volts are rated for up to 15.3 and the amps are either 25 or 50. These stages combined sequentially form what is commonly called the “charging algorithm.” A battery charger may generally be classified by a charging current (i.e. Here are a few FAQ videos that talk about charging LiFePO4 batteries. The final charge conditions was 14.65V at 270 mA. Since it is Bluetooth enabled, you are also able to see some charging information on the app as well. Free ground shipping in the 48 states. In setting up the BMK, it ask me to set the “charge efficiency factor” from the Battery manufacturer or leave it the in auto default. Max Charge rate? If you want to get more information about these various conditions you can give us a call at 855-292-2831 or email us at [email protected] and one of our sales and tech specialists can help you. If you have any other questions or want to talk about all things batteries, you can call our team at 855-292-2831. CHARGE PARAMETER 12V SYSTEM 24V SYSTEM 48V SYSTEM Bulk Voltage 14V – 14.6V 28V - 29.2V 56V - 58.4V Absorption Voltage 14V – 14.6V 28V - 29.2V 56V - 58.4V Absorption Time 0- 15 min 0- 15 min 0- 15 min We don’t have a specific % increase or decrease calculation for these temperatures but around 70F is optimal for maximum life expectancy. What Is A Lithium Trolling Motor Battery? There is no actual charge profile on this unit, and the maximum wire gauge recommended is 10 gauge. This will make the nominal voltage of a LiFePO4 12.8V. cjn. https://battlebornbatteries.com/lead-is-dead-white-paper-study/, https://battlebornbatteries.com/wp-content/uploads/2020/10/Lead-is-Dead-Cold-Charging-LFP-vs-Lead-Acid.pdf, https://battlebornbatteries.com/boondocker/, https://www.progressivedyn.com/rv/charge-wizard/pd92201-converter-status-remote-pendant/. The motorhome is on shore power most of the time, so it can be months between the batteries being called upon – but they have always worked when needed. Your manual states… “For your Bulk/Absorption stage, the ideal voltage is between 14.2v-14.6v.” This suggests a fixed voltage, rather than a current limited bulk stage. We always recommend charging the batteries completely before the initial use. Seems you are you saying you can charge BB 100ah batteries at 100 amps? There is very little useable energy between 3.4v and 3.6v with the LiFePo4 chemistry and the voltage drop will reflect this when the battery is in use. The charger has a lifepo4 setting but the converter can only charge at a constant voltage. Most of the time if it is warm I will be plugging in at night and the Victron Multiplus 3000 can charge the batteries. And lastly, I have a 30 volt -10 amp regulated power supply that I think I can use with a voltage limit of 14.2 or so. 435AmH . Our team is reviewing our verbiage to make sure we better reflect this. Hi in normal driving it seems to stay at 14.2v. I am looking at sterling power 30 and 60 amp dc to dc chargers. The lithium battery charger can behave in several different ways during the charging process. 12.2V is 50% SoC for a battery that has been sitting at rest for an extended period, typically 24 hours. also what voltage setting would be the best for your battery? You can call us at 855-292-2831 or send an email to [email protected] if you have any additional questions as well. Could I charge this battery with jumper cables connected to a running car battery? 12 Volt high-power, high capacity lithium iron phosphate packs. Charging completed in about 2 hours with 1150 Wh in. Lifepo4 Lithium Battery Factory 12V 24V 48V 96V from 7AH to 1000AH. To figure this time out we recommend 20-30 min per battery (For example if you have 2 batteries set it for 1 hour). Thank you and have a great day. You can find the blog here: https://battlebornbatteries.com/lead-is-dead-white-paper-study/ The full charge voltage of a 12V SLA battery is nominally around 13.1 and the full charge voltage of a 12.8V lithium battery is around 13.4. This will allow you to set a specific charge profile compatible with our batteries, and will ensure proper charging. What is your suggested charge rate for two batteries? In regard to the temperature compensation, we modeled this experiment after a typical customer experience, so temperature compensation was not included, as most customers would not implement this in their own system. LiFePO4 Discharge Voltage vs. SOC Most of the time during discharge, the battery Voltage will be right around 13.2 Volt. Is there an upper limit to the charging amps the battery can handle safely? If left at a half charge, the batteries have the potential to not last as long in storage. and decide how fast you want to charge your battery. We recommend a bulk and absorption voltage of 14.4 V. A float is unnecessary, since li-ion batteries do not leak charge, but a floating voltage under 13.6 V is fine. The Intelipower 9200 Charge Wizard chargers will work great with our batteries, but you need to use the 9200 Wired Remote Pendant to force the converter to output a proper voltage in the BOOST MODE. Also join us on Facebook, Instagram, and YouTube to learn more about how lithium battery systems can power your lifestyle, see how others have built their systems, and gain the confidence to get out there, and stay out there. Charging a LiFePO4 battery basically means applying an external voltage to drive current from the anode to the cathode of the battery. Once you’ve scrolled to the correct number press this setting to confirm. it’s better to charge your bank at less than 100% for longevity. I have a Magnum hybrid inverter with the ME-BMK. For alternator charging, we recommend using the Victron 12/12 – 30 Smart Charger for a number of reasons. Hi Greg, thanks for reaching out. Nominal Voltage: 12.8V: Nominal Capacity (at .5C, 77°F) 100Ah: Minimum Capacity (at .5C, 77°F) 95Ah: Expected Cycle Life >4000 cycles w/1C charge and discharge rate, at 77°F, 80% DOD: Operating Specifications : Charge Method: Smart charger, constant current, constant voltage: Charge Voltage Range (Max 14.6V) 14.4 -14.6V: Continuous Charge Current: 100A Max It should now show “Set max charge Amps” and scroll until you reach the appropriate amperage. 14.1 volts would be fine to set it to. The lithium battery charger acts as a pump, pumping current upstream, opposite the normal direction of current flow when the battery discharges. LiFePO4 batteries' state of charge versus charging voltage As the title says. We don’t limit this in case the end user needs to apply a quicker charge to the battery based on their specific scenario and aren’t worried about the potential shortening of cycles that can occur by this higher charge rate. This will need manual interaction each time you want to fully charge the battery, and our team recommends doing it once a week or so. Depends on which LiFePO4 cells we're talking about. I assume as long as the max output of the alternator does not exceed 100amps of continuous current? Maintenance-free S ealed L C ad-acid Batery ONSTANT VOLT AGE CH RGE BATTERYMUSTBERECYCLED Standby use: 13.5-1 SC-122420JUD - this is the PWM version optimized for portability, can do 12V or 24V at 20A maximum and is the unit you would select for portable use. This article was suppose to be talking about charging lifepo4 batteries but it instead talks about lead acid battery charging. Hey Ernie! Or adding a 2nd battery, (yours), wired in parallel or connected to the load and separately connected to the car through say the 12v cigar lighter. I can only speak for our 100AH batteries. I have moved the alternators to the start battery & a Sterling Power BBW12120 will charge the BB10012 house bank when underway. You can install a DC light fixture with an incandescent bulb if the compartment is well insulated or use a warming pad to keep the batteries above freezing. I plan to use it for a trolling motor on a small car top boat. PowerBrick+ 24V-32Ah; PowerBrick+ 24V-50Ah; PowerBrick+ 24V-150Ah; 48V Lithium Battery Pack Thank you so much for the content on batteries! It should now read “Set Recharge Volts” and scroll until it reads 13.3V. If you have any other questions please feel free to give us a call at 855-292-2831 or send an email to [email protected]. There are many different factors in play with this system and it will require a phone conversation in order to work out the details. Hi Jeff, thanks for your comment. This unit has a simple rotary dial that the output voltage can be set to; we recommend 14.4v for Battle Born Batteries. In an emergency situation the battery can be charged at a quicker rate if needed. (855) 292-2831 I have two 100amp 12V battleborn batteries in my van. Charging Lithium batteries requires a voltage in between 14.2-14.6 volts for bulk/absorption, 13.6 or lower for float and should not have an equalization stage. SC-1220JU - this is the MPPT version in 12V only with 20A maximum rated output and is optimized for fixed installations utilizing LiFePO4 batteries and does not come with a digital display. etc. I have a lifepo4 with a BMS and trying to charge via alternator in my truck. The batteries will have effectively NO load on them, and will always be at 100% SOC. It should now read “Set CV Charge Volts” and scroll until it reads 14.4V then press to confirm this. not require equalizing. During this stage, the charger adjusts its applied voltage to deliver the maximum current to the battery. I just reviewed the instructions above and confirmed that I have set everything correctly (a year ago when I installed the system.) Hello Crosby, Best thing to do is contact the mfg of the battery and ask them for the charging parameters. What Battery Cable Size Should I Use For My RV? Our tech team suggests that there are no additional steps that are necessary as long as there is no power applied to the unit when unoccupied. Vehicles charge lead acid to 14.40V (2.40V/cell) and maintain a topping charge. If you have a Sterling DC to DC charger (30 amp) For a 6 x100 BB battery bank will it cause damage? With four Li-phosphate cells in series, each cell tops at 3.60V, which is the correct full-charge voltage. Thanks. the max charging current) and a target battery voltage (12 V, 24 V, 36 V, 48 V, etc.). i›ºªÅò™deµlJu)ù$fi]‚¹¿Ûlœ»zl9}ő7èÞÔëæ›TÁY%m݈ˆ&+ZÍØ¸wàÙÜèõuÀñÕà¢aúÁ¾…#k+²ów¤4¦ÀqÚ1‘5Ô>AFŝ±Ž8£]>"ÍÜ!^K‡Iž9T«ñäësD•¼0…9. Unlike gel or lead-acid batteries, the VoltaX LiFePO4 battery is extremely portable and has a longer shelf-life. Battery capacity is measured in mAh (milliamp-hours), being the amount of Each LiFePO4 cell has a NOMINAL voltage of 3.3V. Here are a few FAQ videos that talk about charging LiFePO4 batteries. so just wondering a ballpark charge time for 1 of your 100ah batteries with using a Renogy 12v 40A DC-DC charger. I apologize in the delay of getting back to you with this answer. In case you missed my earlier post, regarding the low temp disconnect of the internal BMS. As for the article, we are currently rewriting these blogs and creating a new FAQ series, so stay tuned for those updates. What is the reserve capacity of your batteries? The battery’s are the Trojan L16H-AC w T2 technology You will need to scroll to set the appropriate amount of time. But you seemed to skip over “Set Max CC/CV Time, ” implying that it should be left at a default value. I would check with your battery manufacturer to answer this question for you. Alternatively, if you don’t want to or can’t use the custom settings then they can just set the retome to the “AGM2” battery type and it will still work well to charge our batteries. Thanks in advance for your help. The Renogy DC to DC charger should take around 2.5 to 3 hours to fully charge a 100 amp battery if there are no significant loads being drawn. You can use dip switch 5 to choose between lead acid battery types and lithium. Thanks~. So, a 100 Ah 12V battery has 1200 Wh of energy (100 * 12 = 1200). I understand the reasoning for using some type of DC-to-DC charger/converter but ….. So, instead of turning off, the battery charger enters a third stage called the “float” stage, in which the charger drops to a lower voltage and holds at that voltage. I’m trying to understand the best way to charge a Lifepo4 battery from my alternator. I was hoping to actually get information on charging lifepo4 under various conditions like cold. All in all, the length of time it takes to charge a li-ion deep cycle battery depends on the type and size of your charging source. Hello Our only concern would be a higher fixed voltage for an extended period of time at 14.2 or greater. These parameters can be customized for Battle Born Batteries with the use of the Victron Connect App as it’s a Bluetooth enabled device. Press to confirm. We are looking to replace the 220GXL batteries but keep the APC-UPS. I have been doing some research on battery restoration and I think this content may help anyone looking into this product for more help – https://bit.ly/3nlQMN8. We currently use 2 external Alphacell 220 GXL 109AH batteries in serial, connected to an APC Smart-UPS 700. As such, resting voltage is a very poor indicator of remaining capacity. Please post/share a table or graph of charge current vs. state of charge for fixed charge voltage, such as 14.6V. I understand that your internal BMS has a low temp disconnect to prevent damaging the cells when charging when the batteries are too cold. Voltage range: 3.2V - 12V – 24V – 48V – … Required fields are marked *, Free ground shipping in the 48 states • 10-year warranty on all batteries. The Standard range uses high quality LiFePO4 Lithium cells which allow to reach 2000 cycles at 100% depth of discharge at 1C. At this point, the battery is fully charged. If you are storing your entire system, we recommend the use of a battery guardian to help protect your batteries by disconnecting them from parasitic loads once they reach a voltage of 11.5V. Our Reno, Nevada-based sales and customer service team is standing by at (775) 622-3448 to take your questions! I hope to use a 12v 100ah battery in my van and intend to use a DC – DC charger. please give us a call if you have any other questions. Welcome customize shell,weight, size,MBS,technology,etc ! You are welcome to reach us at [email protected] or give us a call at 855.292.2831. It is super helpful to know the inter-workings of the batteries and charging. Recently installed my 2 100AH Battleborn Batteries in my RV and programmed my solar and inverter/charger to your recommended specs. It’s currently winter and I’ve got my camper covered and stored. The screen should now say “Set CV Chg Done Time” then press to select this option, Now it should say “Set CV Chg Done Time”. And a follow on question is: why doesn’t the BMS limit the charge current to the recommended C/2 (50 amps for the 100ah battery)? LiFePO4 … We believe you are meaning to respond to our white paper blog. Or will the BMS provide this function? In my application would you advise that I add external charger disconnects to prevent accidental charging, such as from solar panels, until I’m sure the battery warms above freezing? Adding another battery in the future will not be an issue, again just bring all the batteries to a full state of charge before using. My question is weather you recommend I install additional charger disconnects to protect the battery from charging in freezing conditions or is the BMS designed to disconnect and reconnect when temp rises to a safe level. 100 Amp Continuous Current The unit for capacity is Watt-hours (Wh) and the formula for Watt-hours is the Amp-hour rating times the nominal voltage. Our suggested charge rate is 50 amps max for a single battery, but be aware that the battery can accept a higher charge rate if this is needed by the end user. We also are publishing an FAQ blog post on winterizing your batteries later this month, so stay tuned. Ideally we want our battery to regularly reach a 100% SOC. The cycle life of LiFePO4 battery is generally more than 2000 times, and some can reach 3000~4000 times. The Victron MPPT charge controllers allow you to set the absorption time(and voltage 14.4v) to the desired level. In your case, having a constant 14.6V is acceptable for the batteries but the batteries don’t necessarily draw power from your charger, they will accept whatever amount of charge your charger puts into them. Hi Chuck, I apologize for the delay in getting back to you. Advantages or disadvantages to either with your batteries. I have a pd4655 liv and a 3210an Epever Tracer for my 100 amp Battleborn. Our sales and tech team is more than happy to help as well, if you give them a call at 855-292-2831 they can walk you through the process live as well. Hi James, please give us a call at 855-292-2831 so we can confirm everything and run through your system. Shouldn’t they be resting/floating most of the time? Absorb done? The charge Amp. The higher the amp rating (A) of the charger, the faster your battery will charge*. In addition, these cells are sorted and matched for the constitution of the pack. They are all connected together for one 12v bank. I’ll keep an eye out for excess current which trips the breaker. You explain Peukert, and you are familiar with that dude… you know.. Ohm and his law. Scroll through setup options until you see “03 Charger Setup” then press to select this option We don’t make 200AH batteries, so I’m assuming these are another manufacturers batteries. Make sense? It would charge the 200 ah bank in a little over 3 hours while the 30 amp would do it in 6 hours. But they can be in float mode as long as the float is around 13.6, it is OK for the batteries to float around that voltage. The battery voltage had dropped to 11.5V with the load switched off. it has, 14v, 14.2v, 14.4v 14.6v. First, the charger can steadily increase its voltage in order to keep the current flow constant. Is that correct? Hi Corey, thanks for your feedback! All Rights Reserved. At 5 minutes of charging, 13.26 V at 50 A. I also have two of the old transformer based 12 volt chargers, a 6 amp Schumacher SE-82-6 and a 15 amp Everstart that I think are safe to use, but would like to hear it from you, if you know. When the charger’s applied voltage is higher than the open-circuit battery voltage, then the charging current flows. These voltages work very well with your typical 12V, 24V, and 48V inverters. without subtitles or text translation of vids they are useless for your deaf customers. Press to confirm. At the coldest temp, you’d be at almost 16V for a proper absorption charge. Our batteries do not require a float charge. That would be a great charger to be compatible with our batteries as long as it has what’s in this image. Battery. There is a wide variation among values for charging algorithms for lead-acid batteries. This is then connected to a transfer switch which switches from wall outlet power to inverter power in the event of a power failure. I frequently use my RV in below freezing conditions in the winter. They can be left for many months at a time with the proper multistage charger available. Do you sell smaller batteries? Scroll through the menu options until you reach “Setup” then press to select

Royce Da 5 9 Pharrell, Why The Fuss Everquest Guild, Best Nycha Developments In Brooklyn 2019, Sox Controls Examples, Diy Tennis Ball Launcher, Raeven Khan Age, Hp Pavilion Laptop Hard Drive Replacement, Animal Crossing: New Horizons Pattern Maker,

Leave Comment